pl gb ru ltby

Automatic Set SMOK with a cast iron burner

  • AZSB-30kW-GZ-06m
  • AZSB-60kW-GZ-2m
  • AZSB-120kW-GZ-2m
  • AZSB-120kW-GZ-nagarniacz
  • AZSB-240kW-GZ-6m
 
FUEL



ZrębkiTrocinyKora

SAWDUST, SHAVINGS, BARK OF A TREE, BRIQUETTE, AGRO-BRIQUETTE,
PELLET, FRUIT STONES

  • Automatic Biomass Burning Set - SMOK is a modern device composed of an exchanger, feeding system, fuel burning head, fuel container or a spring sweeper.
    The unique design of the exchanger and its automatic fuel feeder ensure that its operation is maintenance-free, highly efficient, and produces low emissions that comply with EN 303-5 norm. A wide range of fuel containers (0.6 - 1 - 2 - 4 - 6 - 8 - 10 - 27 m3) allows fuel to be loaded every 2-6 days, depending on the type and calorific value of the fuel. The SMOK sets with cast iron heads are suitable for burning dry renewable fuels, with moisture content not exceeding 25% (wood shavings, chips, sawdust, bark, wood briquette, agro-briquette, fruit seeds, etc.).
    The combustion process is controlled automatically with modern controllers by PLUM.

    With fuel moisture content ranging from 25% to 40%, ceramic heads are used (powered at 30-50-100-240 kW), while with drier fuels with moisture content of up to 25% we recommend cast iron heads (powered at 30-60-120-180-240 kW).

    Our offer includes SMOK sets with a spring sweeper used instead of a fuel container.
    The spring sweeper allows utilizing an existing room as the fuel container. Innovative construction solutions allow adopting the device to boiler rooms with various sizes and layouts - regulated rise angle of the feeder and turning of the head in relation to the level of the feeder.
  • Set SMOK
    Fuel container volume m3 0,6 1 2
    Efficiency % 84
    Water volume L 90
    Working temp. of heating water °C 70-80
    Min. temp. of return water °C 55
    Working pressure bar max. 1,5
    Power supply V 400V/50Hz
    Chimney height  m 8-10
    Min.chimney diameter cm2 / Ø mm  324/180
    TECHNICAL DRAWINGS
    /with dimensions/
      PDF ikona DOWNLOAD PDF ikona DOWNLOAD PDF ikona DOWNLOAD
  • Set SMOK
    Fuel container volume m3 1 2 4 6 8 10
    Efficiency % 84
    Water volume L 190
    Working temp. of heating water °C 70-80
    Min. temp. of return water °C 55
    Working pressure bar max. 1,5
    Power supply V 400V/50Hz 
    Chimney height  m 8-10
    Min.chimney diameter cm2 / Ø mm  506/225
    TECHNICAL DRAWINGS
    /with dimensions/
      PDF DOWNLOAD PDF DOWNLOAD PDF DOWNLOAD PDF DOWNLOAD PDF DOWNLOAD PDF DOWNLOAD

    Set SMOK equipped with spring agitator
    Thermal power Length agitator Water
    volume
    Arm
    length
    Max. fuel
    stack height
    Power
    requirement
    Power supply Weight TECHNICAL DRAWINGS
    60 kW 3 m 190 L ☐ 3 m 3 m 1950 W 400V/50Hz 1020 kg PDF DOWNLOAD
    4 m 190 L 1950 W 1050 kg PDF DOWNLOAD
  • Set SMOK
    Fuel container volume m3 2 4 6 8 10
    Efficiency % 84
    Water volume L 480
    Working temp. of heating water °C 70-80
    Min. temp. of return water °C 55
    Working pressure bar max. 1,5
    Power supply V 400V/50Hz
    Chimney height  m 8-10
    Min.chimney diameter cm2 / Ø mm  900/300
    TECHNICAL DRAWINGS
    /with dimensions/
      PDF DOWNLOAD PDF DOWNLOAD PDF DOWNLOAD PDF DOWNLOAD PDF DOWNLOAD

    Set SMOK equipped with spring agitator
    Thermal power Length agitator Water
    volume
    Arm
    length
    Max. fuel
    stack height
    Power
    requirement
    Power supply Weight TECHNICAL DRAWINGS
    120 kW 3 m 480 L ☐ 3 m 3 m 2130 W 400V/50Hz 1800 kg PDF DOWNLOAD
    4 m 480 L 2130 W 1830 kg PDF DOWNLOAD
  • Set SMOK
    Fuel container volume m3 4
    6 8 10 27
    Efficiency % 84
    Water volume L 720
    Working temp. of heating water °C 70-80
    Min. temp. of return water °C 55
    Working pressure bar max. 1,5
    Power supply V 400V/50Hz
    Chimney height  m 8-10
    Min.chimney diameter cm2 / Ø mm  1225/350
    TECHNICAL DRAWINGS
    /with dimensions/
      PDF DOWNLOAD PDF DOWNLOAD PDF DOWNLOAD PDF DOWNLOAD PDF DOWNLOAD


    Set SMOK equipped with spring agitator
    Thermal power Length agitator Water
    volume
    Arm
    length
    Max. fuel
    stack height
    Power
    requirement
    Power supply Weight TECHNICAL DRAWINGS
    180 kW 4 m 720 L ☐ 3 m 3 m 2130 W 400V/50Hz 2900 kg PDF DOWNLOAD
  • Set SMOK
    Fuel container volume m3 4
    6 8 10 27
    Efficiency % 84
    Water volume L 1020
    Working temp. of heating water °C 70-80
    Min. temp. of return water °C 55
    Working pressure bar max. 1,5
    Power supply V 400V/50Hz
    Chimney height  m 8-10
    Min.chimney diameter cm2 / Ø mm  1600/400
    TECHNICAL DRAWINGS
    /with dimensions/
      PDF DOWNLOAD PDF DOWNLOAD PDF DOWNLOAD PDF DOWNLOAD PDF DOWNLOAD


    Set SMOK equipped with spring agitator
    Thermal power Length agitator Water
    volume
    Arm
    length
    Max. fuel
    stack height
    Power
    requirement
    Power supply Weight TECHNICAL DRAWINGS
    240 kW 4 m 1020 L ☐ 3 m 3 m 2240 W 400V/50Hz 3100 kg PDF DOWNLOAD
  • INSTRUCTIONSTO DOWNLOAD
    Instruction manual for 40-240 kW Smok Automatic Biomass Burning Set
    with cast iron heads, 4-27 m3 containers, and spring sweepers
    PDF ikona DOWNLOAD
    Instruction manual for 30-120 kW Smok Automatic Biomass Burning Set
    with cast iron heads and containers of up to 2m3
    PDF ikona DOWNLOAD
    Operating Instructions "Smok" 30-240kW - Automatic Biomass Burning Set PDF ikona DOWNLOAD
    INSTALLATION AND OPERATION MANUAL SMOK-3 boiler control cubicle PDF ikona DOWNLOAD
    INSTALLATION AND OPERATION MANUAL SMOK-4 boiler control cubicle PDF ikona DOWNLOAD
    Operation and maintenance manual Multi-Ster PDF ikona DOWNLOAD
    Operation and maintenance manual ZAB-07, ZAB-12
    (for solid fuel-fired boilers with feeding screw)
    PDF ikona DOWNLOAD
    Operation and maintenance manual ZAB-14 - FOR BIOMASS BOILERS WITH TWO FEEDERS PDF DOWNLOAD
    Internet module ecoNET300 - operation and installation manual PDF DOWNLOAD
    Room panel ecoSTER 200 PDF DOWNLOAD
    Room panel ecoSTER TOUCH for ecoMAX boiler controller PDF DOWNLOAD