pl gb ru ltby

Unica Sensor

Power type series: 10 kW, 15kW, 20kW, 25kW, 30kW, 40kW, 50kW, 60 kW
  • UNICA SENSOR 10-15kW-Moderator
  • UNICA SENSOR 20-30kW-Moderator
  • UNICA SENSOR 40-60kW-Moderator
 
FUEL

wegieldrewnowegiel mial

HARD COAL, WOOD,
HARD COAL/COAL DUST


  • The UNICA SENSOR is a low temperature water heating boiler with a steel frame. Triple chamber design of the heat exchanger allows highly effective combustion of various types of fuels. The boiler utilizes a directional separation of air into primary and secondary air, which has a signifi cant infl uence on its operationg costs and environmental impact.

    warranty3 3 YEARS
    WARRANTY
     0026 stal-atestowana-kotlowa-6mm CERTIFIED
    BOILER STEEL
    6 MM
     0043 sprawnosc-84 HIGH
    EFFICIENCY - 84%
     0039 pojemna-komora-spalania LARGE
    COMBUSTION
    CHAMBER
     0038 szeroka-klapa-zasypowa WIDE LOAD
    HATCH
     0028 podwojny-rozdzial-powietrz-w-komorze-paleniskowej DOUBLE AIR
    SEPARATION IN FIREPIT
     0025 nowoczesny-wielofunkcyjny-sterownik-z-funkcja-fuzzy-logic MODERN
    MULTIFUNCTIONAL
    CONTROLLER
     0037 latwy-dostep-do-czyszczenia EASY
    CLEANING ACCESS
     0036 wysoka-stalopalnosc-- HIGH
    BURNING STABILITY
     0035 czujnik-temperatury-spalin-opcja FLUE GAS
    TEMP. SENSOR - OPTIONAL

    Equipment
    cleaning kit, thermometer, ember safety grille, moving grate lever,
    ash drawer (10-26 kW)
    Warranty
    3 YEARS
  • UNICA SENSOR 10 kW15 kW20 kW25 kW30 kW40 Kw50 Kw60 KW
    Efficiency % 83,6
    Water volume L 40 61 78 90 105 120 135 155
    Boiler mass kg 186 214 249 283 330 391 429 466
    Load chamber volume dm3 43 61 66 88 120 154,5 179,5 204,5
    Working temp. of heating water °C 70-80
    Min. temp. of return water °C 55
    Working pressure bar max. 1,5
    Power supply V 230
    Power requirement W 70
    Load hatch diameter cm x cm 22-31,5 22-39
    Chimney height  m 8-10
    Min.chimney diameter cm2 / Ø mm  324/180 400/200 625/250 900/300
    Dimensions PDF
  • Unica-Sensor przekroj
  • czujnik spalinThe controller in UNICA SENSOR boilers, apart from the regular sensors, is also equipped in an exhaust gas temperature sensor (additional equipment).
    Thanks to this sensor – the temperature of the gases in the flue is constantly monitored by the controller, and in case of its significant rise, the ventilator is slowed down or stopped. Using a flue gas sensor we save up to 15% of fuel, and the temperature of the supply water is very stable, which increases the lifetime of the exchanger (boiler). Controlling the temperature of the flue gasses leaving the boiler also helps to reduce the emission of dust and gasses which are harmful to the environment. The heat energy of the flue gasses is not wasted and released into the atmosphere, but rather applied to heating the premise.
  • Operating Instructions UNICA SENSOR 10 ÷ 60kW Boilers
    Boiler regulator ecoMAX 200 W